Fire cut
In the construction of masonry buildings, a fire cut[1] or fireman's cut is a diagonal chamfer of the end of a joist or beam where it enters a masonry wall. If the joist burns through somewhere along its length, damage to the wall is prevented as the fire cut allows the joist to fail and still leave the masonry wall standing.
Without firecut joists, if the burnt joists fail and rotate the unchamferred ends of the joists as they deflect downwards, this would damage the masonry wall at the connection point and possibly pull the wall inwards.
References
- ^ Brannigan, Francis L., and Glenn P. Corbett. Brannigan's building construction for the fire service. 4th ed. Sudbury, MA: National Fire Protection Association :, 2007. Print.
- v
- t
- e
- Backdraft
- Boiling liquid expanding vapor explosion (BLEVE)
- Boilover
- Combustibility and flammability
- Conflagration
- Dangerous goods (HAZMAT)
- Deflagration
- Detonation
- Dust explosion
- Enthalpy of vaporization
- Explosive
- Fire class
- Fire control
- Fire loading
- Fire point
- Fire triangle
- Flammability diagram
- Flammability limit
- Flammable liquid
- Flashover
- Flash point
- Friction loss
- Gas leak
- Heat transfer
- Jet fire
- K-factor (fire protection)
- Pool fire
- Pyrolysis
- Spontaneous combustion
- Structure fire
- Thermal radiation
- Water pressure
- Active fire protection
- Automatic fire suppression
- Condensed aerosol fire suppression
- Detonation flame arrester
- External water spray system
- Fire bucket
- Fire prevention
- Fire protection
- Fire retardant
- Fire-retardant fabric
- Fire retardant gel
- Fire-safe polymers
- Fire safety
- Fire sprinkler system
- Fire suppression system
- Firefighting foam
- Flame arrester
- Flame retardant
- Flashback arrestor
- Fusible link
- Gaseous fire suppression
- Hypoxic air technology for fire prevention
- Inerting system
- Intumescent
- Passive fire protection
- Personal protective equipment (PPE)
- Relief valve
- Spark arrestor
- Tank blanketing
- Vehicle fire suppression system
- Annulus (firestop)
- Area of refuge
- Booster pump
- Compartmentalization (fire protection)
- Crash bar
- Electromagnetic door holder
- Electromagnetic lock
- Emergency exit
- Emergency light
- Exit sign
- Fire curtain
- Fire cut
- Fire damper
- Fire door
- Fire escape
- Fire extinguisher
- Fire hose
- Fire hydrant
- Fire pump
- Fire sprinkler
- Firestop
- Firestop pillow
- Firewall (construction)
- Grease duct
- Heat and smoke vent
- Occupancy
- Packing (firestopping)
- Penetrant (mechanical, electrical, or structural)
- Penetration (firestop)
- Pressurisation ductwork
- Safety glass
- Smoke control
- Smoke damper
- Smoke exhaust ductwork
- Smokeproof enclosure
- Standpipe (firefighting)
and services
- Template:Fire
- Template:Firefighting
- Template:HVAC
- Category
- Commons
This article about a civil engineering topic is a stub. You can help Wikipedia by expanding it. |
- v
- t
- e
This article about the process of building or construction is a stub. You can help Wikipedia by expanding it. |
- v
- t
- e
This article about joinery, woodworking joints, carpentry or woodworking is a stub. You can help Wikipedia by expanding it. |
- v
- t
- e