Feature on some watches for saturation diving

A helium release valve, helium escape valve or gas escape valve is a feature found on some diving watches intended for saturation diving using helium based breathing gas.

Gas ingress problem

When saturation divers operate at great depths, they live under pressure in a saturation habitat with an atmosphere containing helium or hydrogen. Since helium atoms are the smallest natural gas particles—the atomic radius of a helium atom is 0.49 angstrom and that of a water molecule is about 2.75 angstrom—, they are able to diffuse over about five days into the watch, past the seals which are able to prevent ingress of larger molecules such as water. This is not a problem as long as the watch remains under external pressure, but when decompressing, a pressure difference builds up between the trapped gas inside the watch case and the environment. Depending on the construction of the watch case, seals and crystal, this effect can cause damage to the watch, such as the crystal popping off, as diving watches are designed primarily to withstand external pressure.

Solutions development

Some watch manufacturers manage the internal overpressure effect by simply making the case and sealed connected parts adequately sealed or strong enough to avoid or withstand the internal pressure,[1] but Rolex and Doxa S.A. approached the problem by creating the helium escape valve in the 1960s (first introduced in the Rolex Submariner/Sea-Dweller and the Doxa Conquistador): A small, spring-loaded one-way valve is fitted in the watch case that opens when the differential between internal and external pressure is sufficient to overcome the spring force. As a result, the valve releases the gases trapped inside the watch case during decompression, preventing damage to the watch.[2] The original idea for using a one-way valve came from Robert A. Barth, a US Navy diver who pioneered saturation diving during the US Navy Genesis and SEALAB missions led by Dr. George F. Bond. The patent for the helium escape valve was filed by Rolex on 6 November 1967 and granted on 15 June 1970.[3]

Solutions application

Automatic helium release valves usually don't need any manual operation, but some are backed up by a screw-down crown in the side of the watch, which is unscrewed at the start of decompression to allow the valve to operate. As decompressing saturation divers is a slow working conditions requirements regulated process to prevent sickness and any other harmful medical effects,[4][5] the helium release valve does not have to be able to cope with extremely rapid decompression scenarios, that can occur in a material/medical pass-through system lock.

Helium release valves can primarily be found on diving watches featuring a water resistance rating greater than 300 m (1000 ft). ISO 6425 defines a diver's watch for mixed-gas diving as: A watch required to be resistant during diving in water to a depth of at least 100 m and to be unaffected by the overpressure of the breathing gas. Models that feature a helium release valve include most of the Omega Seamaster series, Rolex Sea Dweller, Tudor watches Pelagos, some dive watches from the Citizen Watch Co., Ltd, Breitling, Girard-Perregaux, Anonimo, Panerai, Mühle Rasmus by Nautische Instrumente Mühle Glashütte, Deep Blue, Scurfa Watches, all watches produced by Enzo Mechana, Aegir Watches and selected Doxa, selected Victorinox models, Oris models, TAG Heuer Aquaracer models, and the DEL MAR Professional Dive 1000 watch.

Other watch manufacturers such as Seiko and Citizen Watch Co., Ltd still offer high-level dive watches that are guaranteed safe against the effects of mixed-gas diving without needing an additional opening in the case in the form of a release valve. This is normally achieved through the use of special gaskets and monocoque case construction instead of using the more common screw down case-backs.

Saturation diving water resistance management

To enable changing the time or date during their dive, saturation divers have to act somewhat counterintuitive regarding the water resistance management of their diving watches. On the initial and any later blowdown or compression, most saturation divers consciously open the water-resistant crown of their watches to allow the breathing gas inside to equalize the internal pressure to their storage/living environment.[6] This pressure differential mitigation strategy allows them to later open the water-resistant crown at their storage pressure, to be able to adjust their watch if required during their (often weeks long[7]) saturation period under regularly varying pressure levels between worksites. The storage pressure is generally kept equal or only slightly lower than the pressure at the intended divers' working depth. Opening a watch case (by unscrewing a crown) means expanding its internal volume. In a significantly higher external pressure environment, any expansion will be impeded by this environment. Every opening and closing action of a release valve or crown seal involves a risk of dirt, lint or other non-gaseous matter ingress, that can compromise the proper functioning of the seal and watch.

ISO 6425 divers' watches standard for mixed-gas diving decompression testing

The standards and features for diving watches are regulated by the ISO 6425 – Divers' watches international standard. ISO 6425 testing of the water resistance or water-tightness and resistance at a water overpressure as it is officially defined is fundamentally different from non-dive watches, because every single watch has to be tested. ISO 6425 provides specific additional requirements for testing of diver's watches for mixed-gas diving.[8]

Some specific additional requirements for testing of diver's watches for mixed-gas diving provided by ISO 6425 are:[9]

  • Test of operation at a gas overpressure. The watch is subject to the overpressure of gas which will actually be used, i.e. 125% of the rated pressure, for 15 days. Then a rapid reduction in pressure to the atmospheric pressure shall be carried out in a time not exceeding 3 minutes. After this test, the watch shall function correctly. An electronic watch shall function normally during and after the test. A mechanical watch shall function normally after the test (the power reserve normally being less than 15 days).
  • Test by internal pressure (simulation of decompression). Remove the crown together with the winding and/or setting stem. In its place, fit a crown of the same type with a hole. Through this hole, introduce the gas mixture which will actually be used and create an overpressure of the rated pressure/20 bar in the watch for a period of 10 hours. Then carry out the test at the rated water overpressure. In this case, the original crown with the stem shall be refitted beforehand. After this test, the watch shall function correctly.[10]

Gallery

  • An integrated, automatically operating helium release valve as used by Rolex for the Rolex Sea-Dweller Deepsea variant.
    An integrated, automatically operating helium release valve as used by Rolex for the Rolex Sea-Dweller Deepsea variant.
  • An integrated, automatic helium release valve (at lowermost point of casing) as used by Breitling for the Avenger Seawolf.
    An integrated, automatic helium release valve (at lowermost point of casing) as used by Breitling for the Avenger Seawolf.
  • A manually operated (screw crown principle) helium release valve as used by Omega SA for their Seamaster dive watches, here the Planet Ocean.
    A manually operated (screw crown principle) helium release valve as used by Omega SA for their Seamaster dive watches, here the Planet Ocean.
  • A manually operated helium release valve as used by Enzo Mechana for their entire line of dive watches. Pictured is the EM001 "Sub Hatch"
    A manually operated helium release valve as used by Enzo Mechana for their entire line of dive watches. Pictured is the EM001 "Sub Hatch"

References

  1. ^ Second Opinions A Love Letter To The Unfairly Maligned Helium Escape Valve In praise of a time-honored feature that lets dive watches pass a little gas
  2. ^ Perezcope – The Sea-Dweller Chronicles: Genesis Of The Decompressing Watch
  3. ^ Perezcope – The Doxa HRV
  4. ^ NORSOK STANDARD U-100 Manned underwater operations Edition, 4 June 2014
  5. ^ CCO Ltd - Reinforce the US Navy saturation diving procedures, 10 January 2019
  6. ^ Watch care in a saturation dive system
  7. ^ How Deep Can We Go? by Dennis Guichard December 4th, 2022
  8. ^ ISO 6425/1996 "Divers' Watches" issued by the International Organization for Standardization (ISO)
  9. ^ ISO 6425/1996 "Divers' Watches" issued by the International Organization for Standardization (ISO)
  10. ^ ISO 2281/1990 "Horology -- Water-resistant watches" (text-only) issued by International Organization for Standardization (ISO)
  • Swiss patent CH492246A Montre étanche, MONTRES ROLEX SA, ANDRE ZIBACH, 6 November 1967
  • Technical Perspective What Saturation Diving Really Means (And What Watchmakers Do About It) It's all about the helium, and not getting killed. Jack Forster, 11 July 11 2017, hodinkee.com
  • v
  • t
  • e
Basic equipment
Breathing gas
Buoyancy and
trim equipment
Decompression
equipment
Diving suit
Helmets
and masks
Instrumentation
Mobility
equipment
Safety
equipment
Underwater
breathing
apparatus
Open-circuit
scuba
Diving rebreathers
Surface-supplied
diving equipment
Diving
equipment
manufacturers
Access equipment
Breathing gas
handling
Decompression
equipment
Platforms
Underwater
habitat
Remotely operated
underwater vehicles
Safety equipment
General
Activities
Competitions
Equipment
Freedivers
Hazards
Historical
Organisations
Occupations
Military
diving
Military
diving
units
Underwater
work
Salvage diving
  • SS Egypt
  • Kronan
  • La Belle
  • SS Laurentic
  • RMS Lusitania
  • Mars
  • Mary Rose
  • USS Monitor
  • HMS Royal George
  • Vasa
Diving
contractors
Tools and
equipment
Underwater
weapons
Underwater
firearm
Specialties
Diver
organisations
Diving tourism
industry
Diving events
and festivals
Diving
hazards
Consequences
Diving
procedures
Risk
management
Diving team
Equipment
safety
Occupational
safety and
health
Diving
disorders
Pressure
related
Oxygen
Inert gases
Carbon dioxide
Breathing gas
contaminants
Immersion
related
Treatment
Personnel
Screening
Research
Researchers in
diving physiology
and medicine
Diving medical
research
organisations
Law
Archeological
sites
Underwater art
and artists
Engineers
and inventors
Historical
equipment
Diver
propulsion
vehicles
Military and
covert operations
  • Raid on Alexandria (1941)
  • Sinking of the Rainbow Warrior
Scientific projects
Awards and events
Incidents
Dive boat incidents
  • Sinking of MV Conception
Diver rescues
Early diving
Freediving fatalities
Offshore
diving incidents
  • Byford Dolphin diving bell accident
  • Drill Master diving accident
  • Star Canopus diving accident
  • Stena Seaspread diving accident
  • Venture One diving accident
  • Waage Drill II diving accident
  • Wildrake diving accident
Professional
diving fatalities
Scuba diving
fatalities
Publications
Manuals
  • NOAA Diving Manual
  • U.S. Navy Diving Manual
  • Basic Cave Diving: A Blueprint for Survival
  • Underwater Handbook
  • Bennett and Elliott's physiology and medicine of diving
  • Encyclopedia of Recreational Diving
  • The new science of skin and scuba diving
  • Professional Diver's Handbook
  • Basic Scuba
Standards and
Codes of Practice
General non-fiction
Research
Dive guides
Training and registration
Diver
training
Skills
Recreational
scuba
certification
levels
Core diving skills
Leadership skills
Specialist skills
Diver training
certification
and registration
organisations
Commercial diver
certification
authorities
Commercial diving
schools
Free-diving
certification
agencies
Recreational
scuba
certification
agencies
Scientific diver
certification
authorities
Technical diver
certification
agencies
Cave
diving
Military diver
training centres
Military diver
training courses
Surface snorkeling
Snorkeling/breath-hold
Breath-hold
Open Circuit Scuba
Rebreather
  • Underwater photography
Sports governing
organisations
and federations
Competitions
Pioneers
of diving
Underwater
scientists
archaeologists and
environmentalists
Scuba record
holders
Underwater
filmmakers
and presenters
Underwater
photographers
Underwater
explorers
Aquanauts
Writers and journalists
Rescuers
Frogmen
Commercial salvors
Diving
physics
Diving
physiology
Decompression
theory
Diving
environment
Classification
Impact
Other
Deep-submergence
vehicle
  • Aluminaut
  • DSV Alvin
  • American submarine NR-1
  • Bathyscaphe
    • Archimède
    • FNRS-2
    • FNRS-3
    • Harmony class bathyscaphe
    • Sea Pole-class bathyscaphe
    • Trieste II
  • Deepsea Challenger
  • Ictineu 3
  • JAGO
  • Jiaolong
  • Konsul-class submersible
  • Limiting Factor
  • Russian submarine Losharik
  • Mir
  • Nautile
  • Pisces-class deep submergence vehicle
  • DSV Sea Cliff
  • DSV Shinkai
  • DSV Shinkai 2000
  • DSV Shinkai 6500
  • DSV Turtle
  • DSV-5 Nemo
Submarine rescue
Deep-submergence
rescue vehicle
Submarine escape
Escape set
Special
interest
groups
Neutral buoyancy
facilities for
Astronaut training
Other