Thermodynamic model of decompression

Early model in which decompression is controlled by volume of gas bubbles forming in tissues
Decompression profiles based on the Thermodynamic model compared with the US Navy table for the same depth and bottom time

The thermodynamic model was one of the first decompression models in which decompression is controlled by the volume of gas bubbles coming out of solution. In this model, pain only DCS is modelled by a single tissue which is diffusion-limited for gas uptake and bubble-formation during decompression causes "phase equilibration" of partial pressures between dissolved and free gases. The driving mechanism for gas elimination in this tissue is inherent unsaturation, also called partial pressure vacancy or the oxygen window, where oxygen metabolised is replaced by more soluble carbon dioxide. This model was used to explain the effectiveness of the Torres Straits Island pearl divers empirically developed decompression schedules, which used deeper decompression stops and less overall decompression time than the current naval decompression schedules. This trend to deeper decompression stops has become a feature of more recent decompression models.[1]

Concept

Brian A. Hills analysed the existing decompression hypotheses frequently referenced in the literature of the time, and identified three basic characteristics of comprehensive theoretical approaches to modeling decompression:[2]

  1. The number and composition of tissues involved;
  2. A mechanism and controlling parameters for onset of identifiable symptoms;
  3. A mathematical model for gas transport and distribution.

Hills found no evidence of discontinuity in the incidence of decompression symptoms for exposure/depth variations, which he interpreted as suggesting that either a single critical tissue or a continuous range of tissues are involved, and that correlation was not improved by assuming an infinite range of half times in a conventional exponential model.[2] After later experimental work he concluded that the imminence of decompression sickness is more likely to be indicated by the quantity of gas separating from solution (the critical volume hypothesis) than its mere presence (as determined by a critical limit to supersaturation) and suggested that this implies that conventional (Haldanian) schedules are actually treating an asymptomatic gas phase in the tissues and not preventing the separation of gas from solution.[3]

Efficient decompression will minimize the total ascent time while limiting the total accumulation of bubbles to an acceptable non-symptomatic critical value. The physics and physiology of bubble growth and elimination indicate that it is more efficient to eliminate bubbles while they are very small. Models which include bubble phase have produced decompression profiles with slower ascents and deeper initial decompression stops as a way of curtailing bubble growth and facilitating early elimination, in comparison with the models which consider only dissolved phase gas.[4]

According to the thermodynamic model, the condition of optimum driving force for outgassing is satisfied when the ambient pressure is just sufficient to prevent phase separation (bubble formation). The fundamental difference of this approach is equating absolute ambient pressure with the total of the partial gas tensions in the tissue for each gas after decompression as the limiting point beyond which bubble formation is expected.[2]

The model assumes that the natural unsaturation in the tissues due to metabolic reduction in oxygen partial pressure provides the buffer against bubble formation, and that the tissue may be safely decompressed provided that the reduction in ambient pressure does not exceed this unsaturation value. Clearly any method which increases the unsaturation would allow faster decompression, as the concentration gradient would be greater without risk of bubble formation.[2]

The natural unsaturation, an effect variously known as the oxygen window, partial pressure vacancy and inherent unsaturation, increases with depth, so a larger ambient pressure differential is possible at greater depth, and reduces as the diver surfaces. This model leads to slower ascent rates and deeper first stops, but shorter shallow stops, as there is less bubble phase gas to be eliminated.[2]

Natural unsaturation also increases with increase in partial pressure of oxygen in the breathing gas.[5]

The thermodynamic model is based on the following assumptions:[6]

  • Only one type of tissue is considered, which is the first type to present symptoms of decompression sickness. Other, non-symptomatic, tissues are disregarded as they do not present a problem.
  • The formation of bubble nuclei occurs randomly within the tissues, and at various levels of supersaturation.
  • Once a bubble nucleus has formed within a supersaturated tissue, dissolved gas in the tissue will diffuse through the bubble surface until equilibrium is reached between pressure in the bubble and concentration in the adjacent tissue.
  • Phase equilibration occurs within a few minutes.
  • Once bubbles have formed they have a tendency to coalesce, causing pressure on the tissues and nerves, which will eventually cause pain.
  • Once bubbles have formed, they are only eliminated by diffusion due to inherent unsaturation.

The requirement to maintain an ambient pressure high enough to prevent bubble growth leads to a significantly deeper first stop than the dissolved phase models which assume that bubbles do not form during asymptomatic decompression.[6]

This model was a radical change from the traditional dissolved phase models. Hills was met with considerable skepticism and after several years of advocating two-phase models, eventually turned to other fields of research. Eventually, the work of other researchers provided enough impact to gain widespread acceptance for bubble models, and the value of Hills' research was recognised.[6]

Further development

The bubble models of decompression are a logical development from this model. The critical-volume criterion assumes that whenever the total volume of gas phase accumulated in the tissues exceeds a critical value, signs or symptoms of DCS will appear. This assumption is supported by doppler bubble detection surveys. The consequences of this approach depend strongly on the bubble formation and growth model used, primarily whether bubble formation is practicably avoidable during decompression.[7]

This approach is used in decompression models which assume that during practical decompression profiles, there will be growth of stable microscopic bubble nuclei which always exist in aqueous media, including living tissues.[8]

Varying Permeability Model

The Varying Permeability Model (VPM) is a decompression algorithm developed by D.E. Yount and others for use in professional and recreational diving. It was developed to model laboratory observations of bubble formation and growth in both inanimate and in vivo systems exposed to pressure.[9] The VPM presumes that microscopic bubble nuclei always exist in water and tissues that contain water. Any nuclei larger than a specific "critical" size, which is related to the maximum dive depth will grow during decompression. The VPM aims to minimize the total volume of these growing bubbles by keeping the external pressure relatively large, and the inspired inert gas partial pressures low during decompression.

Reduced Gradient Bubble Model

The reduced gradient bubble model (RGBM) is a decompression algorithm developed by Dr Bruce Wienke. It is related to the Varying Permeability Model.[10] but is conceptually different in that it rejects the gel-bubble model of the varying permeability model.[11]

It is used in several dive computers, particularly those made by Suunto, Aqwary, Mares, HydroSpace Engineering,[10] and Underwater Technologies Center. It is characterised by the following assumptions: blood flow (perfusion) provides a limit for tissue gas penetration by diffusion; an exponential distribution of sizes of bubble seeds is always present, with many more small seeds than large ones; bubbles are permeable to gas transfer across surface boundaries under all pressures; the haldanean tissue compartments range in half time from 1 to 720  minutes, depending on gas mixture.[10]

References

  1. ^ Doolette, DJ (2006). "A personal view of Brian Hills' contribution to decompression theory and practice". Journal of the South Pacific Underwater Medicine Society and the European Underwater and Baromedical Society.
  2. ^ a b c d e LeMessurier, D.H.; Hills, B.A. (1965). "Decompression Sickness. A thermodynamic approach arising from a study on Torres Strait diving techniques". Hvalradets Skrifter (48): 54–84.
  3. ^ Hills, B.A. (1970). "Limited Supersaturation versus Phase Equilibration in Predicting the Occurrence of Decompression Sickness". Clinical Science. 38 (2): 251–267. doi:10.1042/cs0380251. PMID 5416153.
  4. ^ Yount, David E.; Hoffman, DC (1984). Bachrach A.J.; Matzen, M.M. (eds.). "Decompression theory: a dynamic critical-volume hypothesis" (PDF). Underwater physiology VIII: Proceedings of the eighth symposium on underwater physiology. Bethesda: Undersea Medical Society. pp. 131–146. Retrieved 9 May 2016.
  5. ^ Van Liew, Hugh D; Conkin, J; Burkard, ME (1993). "The oxygen window and decompression bubbles: estimates and significance". Aviation, Space, and Environmental Medicine. 64 (9): 859–65. ISSN 0095-6562. PMID 8216150.
  6. ^ a b c Powell, Mark (2008). "Specific bubble models". Deco for Divers. Southend-on-Sea: Aquapress. ISBN 978-1-905492-07-7.
  7. ^ Yount, David E. (2002). "Decompression theory - Bubble models : Applying VPM to diving" (PDF). Diving Science. Deep Ocean Diving. p. 8. Retrieved 9 May 2016.
  8. ^ Wienke, BR (1989). "Tissue gas exchange models and decompression computations: a review". Undersea Biomedical Research. 16 (1): 53–89. PMID 2648656. Archived from the original on June 2, 2016. Retrieved 7 March 2016.{{cite journal}}: CS1 maint: unfit URL (link)
  9. ^ Yount, DE (1991). "Gelatin, bubbles, and the bends". In: Hans-Jurgen, K; Harper Jr, DE (Eds.) International Pacifica Scientific Diving... 1991. Proceedings of the American Academy of Underwater Sciences Eleventh Annual Scientific Diving Symposium held 25–30 September 1991. University of Hawaii, Honolulu, Hawaii. Archived from the original on January 13, 2013.{{cite journal}}: CS1 maint: unfit URL (link)
  10. ^ a b c Wienke, Bruce R; O’Leary, Timothy R (13 February 2002). "Reduced gradient bubble model: Diving algorithm, basis and comparisons" (PDF). Tampa, Florida: NAUI Technical Diving Operations. pp. 7–12. Retrieved 12 January 2010.
  11. ^ Campbell, Ernest S (30 April 2009). "Reduced gradient bubble model". Scubadoc's Diving Medicine. Retrieved 12 January 2010. – Bruce Wienke describes the differences between RGBM and VPM

External links

  • Resources from Rubicon Research Repository related to the work of B.A. Hills[usurped]
  • v
  • t
  • e
Underwater diving
Basic equipment
Breathing gas
Buoyancy and
trim equipment
Decompression
equipment
Diving suit
Helmets
and masks
Instrumentation
Mobility
equipment
Safety
equipment
Underwater
breathing
apparatus
Open-circuit
scuba
Diving rebreathers
Surface-supplied
diving equipment
Diving
equipment
manufacturers
Access equipment
Breathing gas
handling
Decompression
equipment
Platforms
Underwater
habitat
Remotely operated
underwater vehicles
Safety equipment
General
Activities
Competitions
Equipment
Freedivers
Hazards
Historical
Organisations
Occupations
Military
diving
Military
diving
units
Underwater
work
Salvage diving
  • SS Egypt
  • Kronan
  • La Belle
  • SS Laurentic
  • RMS Lusitania
  • Mars
  • Mary Rose
  • USS Monitor
  • HMS Royal George
  • Vasa
Diving
contractors
Tools and
equipment
Underwater
weapons
Underwater
firearm
Specialties
Diver
organisations
Diving tourism
industry
Diving events
and festivals
Diving
hazards
Consequences
Diving
procedures
Risk
management
Diving team
Equipment
safety
Occupational
safety and
health
Diving
disorders
Pressure
related
Oxygen
Inert gases
Carbon dioxide
Breathing gas
contaminants
Immersion
related
Treatment
Personnel
Screening
Research
Researchers in
diving physiology
and medicine
Diving medical
research
organisations
Law
Archeological
sites
Underwater art
and artists
Engineers
and inventors
Historical
equipment
Diver
propulsion
vehicles
Military and
covert operations
  • Raid on Alexandria (1941)
  • Sinking of the Rainbow Warrior
Scientific projects
Awards and events
Incidents
Dive boat incidents
  • Sinking of MV Conception
Diver rescues
Early diving
Freediving fatalities
Offshore
diving incidents
  • Byford Dolphin diving bell accident
  • Drill Master diving accident
  • Star Canopus diving accident
  • Stena Seaspread diving accident
  • Venture One diving accident
  • Waage Drill II diving accident
  • Wildrake diving accident
Professional
diving fatalities
Scuba diving
fatalities
Publications
Manuals
  • NOAA Diving Manual
  • U.S. Navy Diving Manual
  • Basic Cave Diving: A Blueprint for Survival
  • Underwater Handbook
  • Bennett and Elliott's physiology and medicine of diving
  • Encyclopedia of Recreational Diving
  • The new science of skin and scuba diving
  • Professional Diver's Handbook
  • Basic Scuba
Standards and
Codes of Practice
General non-fiction
Research
Dive guides
Training and registration
Diver
training
Skills
Recreational
scuba
certification
levels
Core diving skills
Leadership skills
Specialist skills
Diver training
certification
and registration
organisations
Commercial diver
certification
authorities
Commercial diving
schools
Free-diving
certification
agencies
Recreational
scuba
certification
agencies
Scientific diver
certification
authorities
Technical diver
certification
agencies
Cave
diving
Military diver
training centres
Military diver
training courses
Surface snorkeling
Snorkeling/breath-hold
Breath-hold
Open Circuit Scuba
Rebreather
  • Underwater photography
Sports governing
organisations
and federations
Competitions
Pioneers
of diving
Underwater
scientists
archaeologists and
environmentalists
Scuba record
holders
Underwater
filmmakers
and presenters
Underwater
photographers
Underwater
explorers
Aquanauts
Writers and journalists
Rescuers
Frogmen
Commercial salvors
Diving
physics
Diving
physiology
Decompression
theory
Diving
environment
Classification
Impact
Other
Deep-submergence
vehicle
  • Aluminaut
  • DSV Alvin
  • American submarine NR-1
  • Bathyscaphe
    • Archimède
    • FNRS-2
    • FNRS-3
    • Harmony class bathyscaphe
    • Sea Pole-class bathyscaphe
    • Trieste II
  • Deepsea Challenger
  • Ictineu 3
  • JAGO
  • Jiaolong
  • Konsul-class submersible
  • Limiting Factor
  • Russian submarine Losharik
  • Mir
  • Nautile
  • Pisces-class deep submergence vehicle
  • DSV Sea Cliff
  • DSV Shinkai
  • DSV Shinkai 2000
  • DSV Shinkai 6500
  • DSV Turtle
  • DSV-5 Nemo
Submarine rescue
Deep-submergence
rescue vehicle
Submarine escape
Escape set
Special
interest
groups
Neutral buoyancy
facilities for
Astronaut training
Other