Vapour pressure of water
T, °C | T, °F | P, kPa | P, torr | P, atm |
---|---|---|---|---|
0 | 32 | 0.6113 | 4.5851 | 0.0060 |
5 | 41 | 0.8726 | 6.5450 | 0.0086 |
10 | 50 | 1.2281 | 9.2115 | 0.0121 |
15 | 59 | 1.7056 | 12.7931 | 0.0168 |
20 | 68 | 2.3388 | 17.5424 | 0.0231 |
25 | 77 | 3.1690 | 23.7695 | 0.0313 |
30 | 86 | 4.2455 | 31.8439 | 0.0419 |
35 | 95 | 5.6267 | 42.2037 | 0.0555 |
40 | 104 | 7.3814 | 55.3651 | 0.0728 |
45 | 113 | 9.5898 | 71.9294 | 0.0946 |
50 | 122 | 12.3440 | 92.5876 | 0.1218 |
55 | 131 | 15.7520 | 118.1497 | 0.1555 |
60 | 140 | 19.9320 | 149.5023 | 0.1967 |
65 | 149 | 25.0220 | 187.6804 | 0.2469 |
70 | 158 | 31.1760 | 233.8392 | 0.3077 |
75 | 167 | 38.5630 | 289.2463 | 0.3806 |
80 | 176 | 47.3730 | 355.3267 | 0.4675 |
85 | 185 | 57.8150 | 433.6482 | 0.5706 |
90 | 194 | 70.1170 | 525.9208 | 0.6920 |
95 | 203 | 84.5290 | 634.0196 | 0.8342 |
100 | 212 | 101.3200 | 759.9625 | 1.0000 |
The vapor pressure of water is the pressure exerted by molecules of water vapor in gaseous form (whether pure or in a mixture with other gases such as air). The saturation vapor pressure is the pressure at which water vapor is in thermodynamic equilibrium with its condensed state. At pressures higher than vapor pressure, water would condense, while at lower pressures it would evaporate or sublimate. The saturation vapor pressure of water increases with increasing temperature and can be determined with the Clausius–Clapeyron relation. The boiling point of water is the temperature at which the saturated vapor pressure equals the ambient pressure. Water supercooled below its normal freezing point has a higher vapor pressure than that of ice at the same temperature and is, thus, unstable.
Calculations of the (saturation) vapor pressure of water are commonly used in meteorology. The temperature-vapor pressure relation inversely describes the relation between the boiling point of water and the pressure. This is relevant to both pressure cooking and cooking at high altitudes. An understanding of vapor pressure is also relevant in explaining high altitude breathing and cavitation.
Approximation formulas
There are many published approximations for calculating saturated vapor pressure over water and over ice. Some of these are (in approximate order of increasing accuracy):
Name | Formula | Description | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
"Eq. 1" (August equation) | P is the vapour pressure in mmHg and T is the temperature in kelvins. Constants are unattributed. | ||||||||||||||||
The Antoine equation | T is in degrees Celsius (°C) and the vapour pressure P is in mmHg. The (unattributed) constants are given as
| ||||||||||||||||
August-Roche-Magnus (or Magnus-Tetens or Magnus) equation | Temperature T is in °C and vapour pressure P is in kilopascals (kPa). The coefficients given here correspond to equation 21 in Alduchov and Eskridge (1996).[2] See also discussion of Clausius-Clapeyron approximations used in meteorology and climatology. | ||||||||||||||||
Tetens equation | T is in °C and P is in kPa | ||||||||||||||||
The Buck equation. | T is in °C and P is in kPa. | ||||||||||||||||
The Goff-Gratch (1946) equation.[3] | (See article; too long) |
Accuracy of different formulations
Here is a comparison of the accuracies of these different explicit formulations, showing saturation vapor pressures for liquid water in kPa, calculated at six temperatures with their percentage error from the table values of Lide (2005):
T (°C) P (Lide Table) P (Eq 1) P (Antoine) P (Magnus) P (Tetens) P (Buck) P (Goff-Gratch) 0 0.6113 0.6593 (+7.85%) 0.6056 (-0.93%) 0.6109 (-0.06%) 0.6108 (-0.09%) 0.6112 (-0.01%) 0.6089 (-0.40%) 20 2.3388 2.3755 (+1.57%) 2.3296 (-0.39%) 2.3334 (-0.23%) 2.3382 (+0.05%) 2.3383 (-0.02%) 2.3355 (-0.14%) 35 5.6267 5.5696 (-1.01%) 5.6090 (-0.31%) 5.6176 (-0.16%) 5.6225 (+0.04%) 5.6268 (+0.00%) 5.6221 (-0.08%) 50 12.344 12.065 (-2.26%) 12.306 (-0.31%) 12.361 (+0.13%) 12.336 (+0.08%) 12.349 (+0.04%) 12.338 (-0.05%) 75 38.563 37.738 (-2.14%) 38.463 (-0.26%) 39.000 (+1.13%) 38.646 (+0.40%) 38.595 (+0.08%) 38.555 (-0.02%) 100 101.32 101.31 (-0.01%) 101.34 (+0.02%) 104.077 (+2.72%) 102.21 (+1.10%) 101.31 (-0.01%) 101.32 (0.00%)
A more detailed discussion of accuracy and considerations of the inaccuracy in temperature measurements is presented in Alduchov and Eskridge (1996). The analysis here shows the simple unattributed formula and the Antoine equation are reasonably accurate at 100 °C, but quite poor for lower temperatures above freezing. Tetens is much more accurate over the range from 0 to 50 °C and very competitive at 75 °C, but Antoine's is superior at 75 °C and above. The unattributed formula must have zero error at around 26 °C, but is of very poor accuracy outside a narrow range. Tetens' equations are generally much more accurate and arguably more straightforward for use at everyday temperatures (e.g., in meteorology). As expected,[clarification needed] Buck's equation for T > 0 °C is significantly more accurate than Tetens, and its superiority increases markedly above 50 °C, though it is more complicated to use. The Buck equation is even superior to the more complex Goff-Gratch equation over the range needed for practical meteorology.
Numerical approximations
For serious computation, Lowe (1977)[4] developed two pairs of equations for temperatures above and below freezing, with different levels of accuracy. They are all very accurate (compared to Clausius-Clapeyron and the Goff-Gratch) but use nested polynomials for very efficient computation. However, there are more recent reviews of possibly superior formulations, notably Wexler (1976, 1977),[5][6] reported by Flatau et al. (1992).[7]
Examples of modern use of these formulae can additionally be found in NASA's GISS Model-E and Seinfeld and Pandis (2006). The former is an extremely simple Antoine equation, while the latter is a polynomial.[8]
In 2018 a new physics-inspired approximation formula was devised and tested by Huang [9] who also reviews other recent attempts.
Graphical pressure dependency on temperature
See also
References
- ^ Lide, David R., ed. (2004). CRC Handbook of Chemistry and Physics (85th ed.). CRC Press. pp. 6–8. ISBN 978-0-8493-0485-9.
- ^ Alduchov, O.A.; Eskridge, R.E. (1996). "Improved Magnus form approximation of saturation vapor pressure". Journal of Applied Meteorology. 35 (4): 601–9. Bibcode:1996JApMe..35..601A. doi:10.1175/1520-0450(1996)035<0601:IMFAOS>2.0.CO;2.
- ^ Goff, J.A., and Gratch, S. 1946. Low-pressure properties of water from −160 to 212 °F. In Transactions of the American Society of Heating and Ventilating Engineers, pp 95–122, presented at the 52nd annual meeting of the American Society of Heating and Ventilating Engineers, New York, 1946.
- ^ Lowe, P.R. (1977). "An approximating polynomial for the computation of saturation vapor pressure". Journal of Applied Meteorology. 16 (1): 100–4. Bibcode:1977JApMe..16..100L. doi:10.1175/1520-0450(1977)016<0100:AAPFTC>2.0.CO;2.
- ^ Wexler, A. (1976). "Vapor pressure formulation for water in range 0 to 100°C. A revision". Journal of Research of the National Bureau of Standards Section A. 80A (5–6): 775–785. doi:10.6028/jres.080a.071. PMC 5312760. PMID 32196299.
- ^ Wexler, A. (1977). "Vapor pressure formulation for ice". Journal of Research of the National Bureau of Standards Section A. 81A (1): 5–20. doi:10.6028/jres.081a.003. PMC 5295832.
- ^ Flatau, P.J.; Walko, R.L.; Cotton, W.R. (1992). "Polynomial fits to saturation vapor pressure". Journal of Applied Meteorology. 31 (12): 1507–13. Bibcode:1992JApMe..31.1507F. doi:10.1175/1520-0450(1992)031<1507:PFTSVP>2.0.CO;2.
- ^ Clemenzi, Robert. "Water Vapor - Formulas". mc-computing.com.
- ^ Huang, Jianhua (2018). "A Simple Accurate Formula for Calculating Saturation Vapor Pressure of Water and Ice". Journal of Applied Meteorology and Climatology. 57 (6): 1265–72.
Further reading
- "Thermophysical properties of seawater". Matlab, EES and Excel VBA library routines. MIT. 20 February 2017.
- Garnett, Pat; Anderton, John D; Garnett, Pamela J (1997). Chemistry Laboratory Manual For Senior Secondary School. Longman. ISBN 978-0-582-86764-2.
- Murphy, D.M.; Koop, T. (2005). "Review of the vapour pressures of ice and supercooled water for atmospheric applications". Quarterly Journal of the Royal Meteorological Society. 131 (608): 1539–65. Bibcode:2005QJRMS.131.1539M. doi:10.1256/qj.04.94. S2CID 122365938.
- Speight, James G. (2004). Lange's Handbook of Chemistry (16th ed.). McGraw-Hil. ISBN 978-0071432207.
External links
- Vömel, Holger (2016). "Saturation vapor pressure formulations". Boulder CO: Earth Observing Laboratory, National Center for Atmospheric Research. Archived from the original on June 23, 2017.
- "Vapor Pressure Calculator". National Weather Service, National Oceanic and Atmospheric Administration.
- v
- t
- e
concepts
- Air changes per hour
- Bake-out
- Building envelope
- Convection
- Dilution
- Domestic energy consumption
- Enthalpy
- Fluid dynamics
- Gas compressor
- Heat pump and refrigeration cycle
- Heat transfer
- Humidity
- Infiltration
- Latent heat
- Noise control
- Outgassing
- Particulates
- Psychrometrics
- Sensible heat
- Stack effect
- Thermal comfort
- Thermal destratification
- Thermal mass
- Thermodynamics
- Vapour pressure of water
- Absorption refrigerator
- Air barrier
- Air conditioning
- Antifreeze
- Automobile air conditioning
- Autonomous building
- Building insulation materials
- Central heating
- Central solar heating
- Chilled beam
- Chilled water
- Constant air volume (CAV)
- Coolant
- Cross ventilation
- Dedicated outdoor air system (DOAS)
- Deep water source cooling
- Demand controlled ventilation (DCV)
- Displacement ventilation
- District cooling
- District heating
- Electric heating
- Energy recovery ventilation (ERV)
- Firestop
- Forced-air
- Forced-air gas
- Free cooling
- Heat recovery ventilation (HRV)
- Hybrid heat
- Hydronics
- Ice storage air conditioning
- Kitchen ventilation
- Mixed-mode ventilation
- Microgeneration
- Passive cooling
- Passive daytime radiative cooling
- Passive house
- Passive ventilation
- Radiant heating and cooling
- Radiant cooling
- Radiant heating
- Radon mitigation
- Refrigeration
- Renewable heat
- Room air distribution
- Solar air heat
- Solar combisystem
- Solar cooling
- Solar heating
- Thermal insulation
- Thermosiphon
- Underfloor air distribution
- Underfloor heating
- Vapor barrier
- Vapor-compression refrigeration (VCRS)
- Variable air volume (VAV)
- Variable refrigerant flow (VRF)
- Ventilation
- Water heat recycling
- Air conditioner inverter
- Air door
- Air filter
- Air handler
- Air ionizer
- Air-mixing plenum
- Air purifier
- Air source heat pump
- Attic fan
- Automatic balancing valve
- Back boiler
- Barrier pipe
- Blast damper
- Boiler
- Centrifugal fan
- Ceramic heater
- Chiller
- Condensate pump
- Condenser
- Condensing boiler
- Convection heater
- Compressor
- Cooling tower
- Damper
- Dehumidifier
- Duct
- Economizer
- Electrostatic precipitator
- Evaporative cooler
- Evaporator
- Exhaust hood
- Expansion tank
- Fan
- Fan coil unit
- Fan filter unit
- Fan heater
- Fire damper
- Fireplace
- Fireplace insert
- Freeze stat
- Flue
- Freon
- Fume hood
- Furnace
- Gas compressor
- Gas heater
- Gasoline heater
- Grease duct
- Grille
- Ground-coupled heat exchanger
- Ground source heat pump
- Heat exchanger
- Heat pipe
- Heat pump
- Heating film
- Heating system
- HEPA
- High efficiency glandless circulating pump
- High-pressure cut-off switch
- Humidifier
- Infrared heater
- Inverter compressor
- Kerosene heater
- Louver
- Mechanical room
- Oil heater
- Packaged terminal air conditioner
- Plenum space
- Pressurisation ductwork
- Process duct work
- Radiator
- Radiator reflector
- Recuperator
- Refrigerant
- Register
- Reversing valve
- Run-around coil
- Sail switch
- Scroll compressor
- Solar chimney
- Solar-assisted heat pump
- Space heater
- Smoke canopy
- Smoke damper
- Smoke exhaust ductwork
- Thermal expansion valve
- Thermal wheel
- Thermostatic radiator valve
- Trickle vent
- Trombe wall
- TurboSwing
- Turning vanes
- Ultra-low particulate air (ULPA)
- Whole-house fan
- Windcatcher
- Wood-burning stove
- Zone valve
and control
- Air flow meter
- Aquastat
- BACnet
- Blower door
- Building automation
- Carbon dioxide sensor
- Clean air delivery rate (CADR)
- Control valve
- Gas detector
- Home energy monitor
- Humidistat
- HVAC control system
- Infrared thermometer
- Intelligent buildings
- LonWorks
- Minimum efficiency reporting value (MERV)
- Normal temperature and pressure (NTP)
- OpenTherm
- Programmable communicating thermostat
- Programmable thermostat
- Psychrometrics
- Room temperature
- Smart thermostat
- Standard temperature and pressure (STP)
- Thermographic camera
- Thermostat
- Thermostatic radiator valve
trades,
and services
- Architectural acoustics
- Architectural engineering
- Architectural technologist
- Building services engineering
- Building information modeling (BIM)
- Deep energy retrofit
- Duct cleaning
- Duct leakage testing
- Environmental engineering
- Hydronic balancing
- Kitchen exhaust cleaning
- Mechanical engineering
- Mechanical, electrical, and plumbing
- Mold growth, assessment, and remediation
- Refrigerant reclamation
- Testing, adjusting, balancing
organizations
- Indoor air quality (IAQ)
- Passive smoking
- Sick building syndrome (SBS)
- Volatile organic compound (VOC)
- ASHRAE Handbook
- Building science
- Fireproofing
- Glossary of HVAC terms
- Warm Spaces
- World Refrigeration Day
- Template:Home automation
- Template:Solar energy